QS

0$
Load capacity : 10 , 20 , 30 , 40 ,50 , 60 Tons Minimum load cell verification intervals(Vmin) : 0.01% Sensitivity (Cn) : 3.0 +/- 0.1% Mv/v Combined error : 0.015% Temperature effect on sensitivity (Tkc) : 0.0012 Temperature effect on zero balance (Tko) : 0.0008 Zero balance : 1.0 % Input resistance (Rlc) : 75 +/- 5 Ohms Output resistance (RO) : 701 +/- 2 Ohms Insulation resistance : >=5000 Ohms Safe overload ; 300% Operating temperature range : -30 to 70oC Recommend excitation : 12 v Maximum excitation : 24 v Material of elastomer : aloy steel / stainless steel Protection class ; IP67/IP68 Citation : OIML R60 / GB751-1997